Infusion Splints

 

 
INDICATIONS
  • Ensure the fixation of the wrist and/or elbow during infusion or dialysis.
 
 
 

 

 

INFUSION SPLINTS FOR BABIES

 

CHRISOFIX SIZES CHRISOFIX MARKING MEASUREMENT
length of the splints
 
1 Children small XXXS 11 cm  
2 Children large XXS 17.5 cm  
3 Extra small XS 22 cm  
       
       

 

  CHRISOFIX SIZES Standard with bandages Standard without bandages Re-usable without bandages
1 401 114 101 401 114 103 401 012 102
2 402 114 101 402 114 103 402 012 102
3 403 114 101 403 114 103 403 012 102
       
       

 

 

DIALYSIS SPLINT

 

CHRISOFIX SIZES CHRISOFIX MARKING MEASUREMENT
length & width of the splints
 
2 Children large XXS 45 cm; 8 cm 612 117 102
4 Small S 53.5 cm; 20 cm 614 117 102
6 Medium M 53.5 cm; 20.5 cm 616 117 102
       
       

 

 

ARTERIAL INFUSION SPLINT

 

CHRISOFIX SIZES CHRISOFIX MARKING MEASUREMENT
length of the splints
 
4 Small S 33 cm 624 117 102
       
       
       
       

 

 

CUBITAL / IV-LINE SPLINT

 

CHRISOFIX SIZES CHRISOFIX MARKING MEASUREMENT
length of the splints
 
6 Medium M 34.5 cm 636 117 102
       
       
       
       

 

 

SPLINT FOR RADIAL ARTERY


MEASUREMENT width of palm                                 REF. NUMBER
      Right Left
S (small) <8 cm   684 022 101 694 022 101
M (medium) 8< cm   686 022 101 696 022 101
         
         
         
   
       

 

Video
 

 

coming soon

GENERAL PRODUCT INFORMATION

 

The main component of the patented Chrisofix® splints is a thin, corrugated aluminium core covered with non allergenic polyethylene foil- and cotton-laminated polyethylene coat at the out- and insight, respectively. Due to perforation, the splints are breathable. They can be applied and perfectly fitted to the injured body part within one minute, without water or heat. The Chrisofix®splints ensure a semicircular stable fixation. The light and comfortable splints limit the mobility of the injured body part to the necessary minimum. They are transparent to X-rays.

 

The Chrisofix® splints are medical devices and not working tools.Damages of the splint resulted from inappropriate use, will be excluded from the product guarantee.

 

POINTS TO CONSIDER WHEN USING THE SPLINTS

 

  • For the first application of the splints (except for first aid cases), professionally competent personal might be requested.
  • The splints are not sterile; do not use on an open wound.
  • Except for first aid cases, splints without a textile lining should only be used on bandaged body parts. Otherwise should be used the padding if supplied with the splint, or an optional material to dress the injured body-part (e.g. tubular bandage).
  • The ready to use Chrisofix® splints can be adjusted directly on the injured body part. When bending and forming, counter-pressure is necessary. Only the rough adjustment must not be performed on any injured body part, but on an adequate model (e.g. on the non-injured part of the body).
  • Fine adjustments – e.g. after soft tissue swelling is reduced, re-adjustments can be made without removing the splint.
  • To avoid injury from sharp metallic edges, the splints must only be bent/adjusted by carefully pressing and never cut.
  • The splints can be fixed into place with optional materials or with the bandage supplied with the splint. If necessary, use only skin friendly, non-aggressive (non-acrylic) adhesive tapes.
  • Frequent bending and stretching of the splints can damage its stability; they must be restricted to the necessary minimum.
  • All Chrisofix® splints and padding are washable with neutral soap water. The splints must be dried at room temperature or a hair dryer at low temperature; infra-red lamp, a microwave oven or laundry dryer must never be used.